Home > Products > Tips > Apical surgery
|
|
Apical surgery
 | Amdent has a number of diamond-coated tips for apical surgery. The tips are used for opening and clearing the root when doing retrograde operations. The long necks of the tips give excellent visibility and the ultrasonic vibrations in combination with the diamond-coating gives a higher degree of tactility and precision compared to rotating instruments. |
|  | Tip AP-3 is at an angle of 80° and has a diameter of 0.5 mm. The outermost 3 mm of the tip is diamond-coated to enable effective removal of tooth substance. AP-3 can be used as a universal tip on all teeth. Recommended power setting: 10-100% with endo function and 10-50% without endo function.
|
|  | Tip AP-4 has the same shape and area of use as AP-3, but is 0.7 mm in diameter making it more suitable for larger roots. Recommended power setting: 10-100% with endo function and 10-50% without endo function.
|
|  | Tip AP-5 is angled at 75° and designed for use on molar roots in the maxillary right and mandibular left. It has 0.5 mm diameter x 3.0 mm diamond coating. Recommended power setting: 10-100% with endo function and 10-50% without endo function.
|
|  | Tip AP-6 is angled at 110° and designed for use on molar roots in the maxillary right and mandibular left. It has 0.5 mm diameter x 3.0 mm diamond coating. Recommended power setting: 10-100% with endo function and 10-50% without endo function.
|
|  | Tip AP-7 is angled at 75° and designed for use on molar roots in the maxillary left and mandibular right. It has 0.5 mm diameter x 3.0 mm diamond coating. Recommended power setting: 10-100% with endo function and 10-50% without endo function.
|
|  | Tip AP-8 is angled at 110° and designed for use on the roots of molars in the maxillary right and mandibular left. Recommended power setting: 10-100% with endo function and 10-50% without endo function.
|
|  | Tip AP-1 is angled at 110° and is used in combination with the instrument holders FH-4 and FH-5. With the aid of the instrument holder the AP-1 can be turned to precisely the angle needed for the treatment. 0.3-0.8 mm diameter x 1.8 mm long and diamond-coated. Recommended power setting: 10-100% with endo function and 10-50% without endo function.
|
|  | Tip AP-2 is angled at 100° and has the same area of use as the AP-1. AP-2 has a slimmer design and is therefore better suited for smaller roots. Recommended power setting: 10-100% with endo function and 10-50% without endo function.
|
|
 |